[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$apiParty6fBuHLCPZ1LTYs42XHdVbjpSDOYYPYzyxeAGwSN5Tp8":3,"$apiPartyhLnLOaTvcBOk0iN4In2XeL6xSXtR0DUYf8379pA2iQs":563,"$apiPartyhLnLOaTvcBOk0iN4In2XeL6xSXtR0DUYf8379pA2iQs$H93EERW16b":563},{"product_data":4,"scene_data":21,"task_data":407,"modality_data":441,"domain_data":478},[5,9,12,15,18],{"name":6,"value":7,"add_value":8,"describe":8},"Rivo","1","",{"name":10,"value":11,"add_value":8,"describe":8},"Cubo","2",{"name":13,"value":14,"add_value":8,"describe":8},"Moye","3",{"name":16,"value":17,"add_value":8,"describe":8},"Juro","4",{"name":19,"value":20,"add_value":8,"describe":8},"Ordo","5",[22,73,135,197,232,267,302,337,372],{"name":23,"value":7,"add_value":24,"describe":25,"children":26},"Home & Indoor","sofa","AI enhances everyday home life. Our datasets cover real indoor scenes to support smart devices, robotics, and home intelligence.",[27,29,31,33,35,37,40,43,46,49,52,55,58,61,64,67,70],{"name":28,"value":7},"Living Room",{"name":30,"value":11},"Bedroom",{"name":32,"value":14},"Kitchen",{"name":34,"value":17},"Dining Area",{"name":36,"value":20},"Bathroom",{"name":38,"value":39},"Entrance \u002F Foyer","6",{"name":41,"value":42},"Corridor \u002F Hallway","7",{"name":44,"value":45},"Staircase","8",{"name":47,"value":48},"Home Office","9",{"name":50,"value":51},"Hobby \u002F Game Room","10",{"name":53,"value":54},"Worship Space","11",{"name":56,"value":57},"Garage","12",{"name":59,"value":60},"Utility \u002F Laundry Room","13",{"name":62,"value":63},"Pantry","14",{"name":65,"value":66},"Basement","15",{"name":68,"value":69},"Garden","16",{"name":71,"value":72},"Balcony","17",{"name":74,"value":11,"add_value":75,"describe":76,"children":77},"Office & Educational","workshop","AI is reshaping work and learning. Our datasets capture offices and classrooms to power automation and next-generation productivity tools.",[78,81,84,87,90,93,96,99,102,105,108,111,114,117,120,123,126,129,132],{"name":79,"value":80},"Open Office","18",{"name":82,"value":83},"Private Office","19",{"name":85,"value":86},"Co-working Space","20",{"name":88,"value":89},"Reception \u002F Lobby","21",{"name":91,"value":92},"Conference Room","22",{"name":94,"value":95},"Huddle Room \u002F Booth","23",{"name":97,"value":98},"Lecture Hall \u002F Auditorium","24",{"name":100,"value":101},"Classroom","25",{"name":103,"value":104},"Science Laboratory","26",{"name":106,"value":107},"Library","27",{"name":109,"value":110},"Design Studio","28",{"name":112,"value":113},"Pantry \u002F Breakroom","29",{"name":115,"value":116},"Cafeteria \u002F Canteen","30",{"name":118,"value":119},"Restroom (Commercial)","31",{"name":121,"value":122},"Gymnasium \u002F Sports Hall","32",{"name":124,"value":125},"Server Room","33",{"name":127,"value":128},"Mailroom \u002F Logistics","34",{"name":130,"value":131},"Janitorial Closet","35",{"name":133,"value":134},"Corridor \u002F Elevators","36",{"name":136,"value":14,"add_value":137,"describe":138,"children":139},"Healthcare & Medical","love-and-help","AI is advancing modern healthcare. Our datasets include clinics and hospitals to enable clinical insights and medical automation.",[140,143,146,149,152,155,158,161,164,167,170,173,176,179,182,185,188,191,194],{"name":141,"value":142},"Operating Theatre \u002F OR","37",{"name":144,"value":145},"Consultation Room","38",{"name":147,"value":148},"Treatment Room","39",{"name":150,"value":151},"Dental Clinic","40",{"name":153,"value":154},"Inpatient Ward","41",{"name":156,"value":157},"Nurse Station","42",{"name":159,"value":160},"ICU","43",{"name":162,"value":163},"NICU (Neonatal ICU)","44",{"name":165,"value":166},"Emergency Room (ER)","45",{"name":168,"value":169},"Hospital Corridor","46",{"name":171,"value":172},"Waiting Area","47",{"name":174,"value":175},"CT\u002FMRI","48",{"name":177,"value":178},"Medical Laboratory","49",{"name":180,"value":181},"Phlebotomy Room","50",{"name":183,"value":184},"Rehabilitation Gym","51",{"name":186,"value":187},"Assisted Living Room","52",{"name":189,"value":190},"Pharmacy","53",{"name":192,"value":193},"Sterile Processing Dept","54",{"name":195,"value":196},"Medical Storage","55",{"name":198,"value":17,"add_value":199,"describe":200,"children":201},"Business & Public Service","business","AI is elevating commercial and public services. Our datasets span retail, dining, and service centers to improve intelligent operations.",[202,205,208,211,214,217,220,223,226,229],{"name":203,"value":204},"Shopping Mall Atrium","86",{"name":206,"value":207},"Supermarket Shelf","87",{"name":209,"value":210},"Self-Checkout Counter","88",{"name":212,"value":213},"Restaurant Dining Hall","89",{"name":215,"value":216},"Commercial Kitchen","90",{"name":218,"value":219},"Hotel Lobby","91",{"name":221,"value":222},"Subway Platform","92",{"name":224,"value":225},"Security Checkpoint","93",{"name":227,"value":228},"Underground Parking","94",{"name":230,"value":231},"Bank Teller Zone","95",{"name":233,"value":20,"add_value":234,"describe":235,"children":236},"Industrial & Manufacturing","robot-arm","AI is modernizing industry. Our datasets capture factories and logistics spaces to support robotics and intelligent manufacturing.",[237,240,243,246,249,252,255,258,261,264],{"name":238,"value":239},"Final Assembly Line","96",{"name":241,"value":242},"Quality Control Station","97",{"name":244,"value":245},"Robotic Welding Cell","98",{"name":247,"value":248},"CNC Machining Center","99",{"name":250,"value":251},"Cleanroom","100",{"name":253,"value":254},"Automated Warehouse","101",{"name":256,"value":257},"Loading Dock","102",{"name":259,"value":260},"Sorting Center","103",{"name":262,"value":263},"Chemical Plant","104",{"name":265,"value":266},"Power Substation","105",{"name":268,"value":39,"add_value":269,"describe":270,"children":271},"Transportation & Driving","car","AI is revolutionizing mobility. Our datasets capture road networks, vehicle dynamics and traffic scenarios to support autonomous driving and intelligent transportation systems.",[272,275,278,281,284,287,290,293,296,299],{"name":273,"value":274},"Urban Intersection","56",{"name":276,"value":277},"Highway \u002F Expressway","57",{"name":279,"value":280},"Tunnel","58",{"name":282,"value":283},"Roundabout","59",{"name":285,"value":286},"School \u002F Hospital Zone","60",{"name":288,"value":289},"Toll Station","61",{"name":291,"value":292},"Construction Zone","62",{"name":294,"value":295},"Parking Garage","63",{"name":297,"value":298},"Driver Cabin","64",{"name":300,"value":301},"Adverse Weather","65",{"name":303,"value":42,"add_value":304,"describe":305,"children":306},"Outdoor & Construction","tent-tree","AI is optimizing outdoor operations. Our datasets capture construction sites, open-air work zones and outdoor infrastructure to support smart construction and autonomous outdoor machinery.",[307,310,313,316,319,322,325,328,331,334],{"name":308,"value":309},"Excavation Site","66",{"name":311,"value":312},"Scaffolding Area","67",{"name":314,"value":315},"Material Storage Yard","68",{"name":317,"value":318},"Site Entrance","69",{"name":320,"value":321},"Roadwork Zone","70",{"name":323,"value":324},"Bridge Infrastructure","71",{"name":326,"value":327},"Transmission Line","72",{"name":329,"value":330},"Open-pit Mine","73",{"name":332,"value":333},"Tunneling Site","74",{"name":335,"value":336},"Post-Disaster Rubble","75",{"name":338,"value":45,"add_value":339,"describe":340,"children":341},"Nature, Aerial & Aquatic","global-loop","AI is exploring the natural world. Our datasets capture terrestrial landscapes, aerial vistas and aquatic ecosystems to support environmental monitoring and autonomous exploration systems.",[342,345,348,351,354,357,360,363,366,369],{"name":343,"value":344},"Deep Forest","76",{"name":346,"value":347},"Farmland \u002F Crops","77",{"name":349,"value":350},"River \u002F Lake","78",{"name":352,"value":353},"Open Ocean","79",{"name":355,"value":356},"Underwater Coral Reef","80",{"name":358,"value":359},"Fish Farm","81",{"name":361,"value":362},"Mountain Terrain","82",{"name":364,"value":365},"Urban Low Altitude","83",{"name":367,"value":368},"Fire Scene","84",{"name":370,"value":371},"Desert \u002F Gobi","85",{"name":373,"value":48,"add_value":374,"describe":375,"children":376},"Virtul & Digital","siri","AI is reshaping the virtual realm. Our datasets capture digital twins, virtual environments and simulated spaces to support metaverse development and intelligent digital interaction.",[377,380,383,386,389,392,395,398,401,404],{"name":378,"value":379},"VR Social Space","106",{"name":381,"value":382},"Synthetic Driving Sim","107",{"name":384,"value":385},"Digital Twin City","108",{"name":387,"value":388},"FPS \u002F MOBA Game","109",{"name":390,"value":391},"Robotics Gym","110",{"name":393,"value":394},"AR Navigation","111",{"name":396,"value":397},"Virtual Showroom","112",{"name":399,"value":400},"Code \u002F IDE Interface","113",{"name":402,"value":403},"App GUI Screen","114",{"name":405,"value":406},"Synthetic Face\u002FID","115",[408,411,414,417,420,423,426,429,432,435,438],{"name":409,"value":7,"add_value":410,"describe":8},"Classification","rubric",{"name":412,"value":11,"add_value":413,"describe":8},"Detection","radar",{"name":415,"value":14,"add_value":416,"describe":8},"Segmentation","segmentation",{"name":418,"value":17,"add_value":419,"describe":8},"Tacking","crosshairs",{"name":421,"value":20,"add_value":422,"describe":8},"Estimation","streamline",{"name":424,"value":39,"add_value":425,"describe":8},"QA","qa",{"name":427,"value":42,"add_value":428,"describe":8},"Recognition","finger-scan",{"name":430,"value":45,"add_value":431,"describe":8},"Control","control",{"name":433,"value":48,"add_value":434,"describe":8},"Extraction","extraction",{"name":436,"value":51,"add_value":437,"describe":8},"Retrieval","retrieval",{"name":439,"value":54,"add_value":440,"describe":8},"Forecast","forecast",[442,445,448,451,454,457,460,463,466,469,472,475],{"name":443,"value":7,"add_value":444,"describe":8},"Audio","audio",{"name":446,"value":11,"add_value":447,"describe":8},"Image","image",{"name":449,"value":14,"add_value":450,"describe":8},"Text","text",{"name":452,"value":17,"add_value":453,"describe":8},"Video","video",{"name":455,"value":20,"add_value":456,"describe":8},"Multi","multi",{"name":458,"value":39,"add_value":459,"describe":8},"Document","document",{"name":461,"value":42,"add_value":462,"describe":8},"Time-Series","time-series",{"name":464,"value":45,"add_value":465,"describe":8},"3D cloud","cloud",{"name":467,"value":48,"add_value":468,"describe":8},"Code","code",{"name":470,"value":51,"add_value":471,"describe":8},"Event","event",{"name":473,"value":54,"add_value":474,"describe":8},"Motion","motion",{"name":476,"value":57,"add_value":477,"describe":8},"Interaction","interaction",[479,482,487,491,494,499,504,509,514,519,524,528,532,536,540,544,548,552,556,559],{"id":480,"value":480,"name":233,"intro":481,"add_value":234,"describe":481},2,"智能质检：利用图像识别、多模态模型对产品外观或声音、振动等数据进行分析，自动识别缺陷，提高质量控制效率。\n工业知识问答与文档理解：通过大模型理解和总结技术文档、操作手册，实现快速问答、知识检索和培训支持。\n安全监测与风险预警：实时分析视频、传感器和操作日志，识别潜在危险行为或异常状态，提前预警，保障人员和设备安全。",{"id":483,"value":483,"name":484,"intro":485,"add_value":486,"describe":485},3,"Finance & Insurance","风险评估与预测：分析大量客户数据，评估信用风险、市场风险等，预测违约概率、股价走势等，辅助金融机构决策。\n智能投顾：根据客户风险偏好、资产状况等，提供个性化投资组合建议，实时调整投资策略。\n反欺诈检测：通过分析交易数据、用户行为，识别异常交易和欺诈行为，保障金融安全。","funds",{"id":488,"value":488,"name":489,"intro":490,"add_value":269,"describe":490},1,"Transport & Automotive","智能座舱：打造多模态交互的 AI 座舱，通过语音、手势、面部识别等实现人机交互，如语音控制导航、音乐播放。\n驾驶员状态监测：识别疲劳、分心、抽烟、打电话等行为，通过大模型判断危险等级，触发相应提醒或干预机制。\n智能驾驶：AI 用于环境感知、路径规划与决策控制，使车辆能识别道路、行人、障碍物等，实现自适应巡航、自动泊车、车道保持等功能，提升驾驶安全性与便利性。",{"id":492,"value":492,"name":136,"intro":493,"add_value":137,"describe":493},4,"医学影像诊断：分析 CT、MRI 等影像，辅助医生检测疾病、识别病灶，如 AI 系统可快速发现肺部结节。\n医患对话助手：通过自然语言处理理解患者问题，提供初步健康建议或就诊指导，缓解医生接诊压力。\n智能健康管理：根据用户健康数据，提供个性化健康建议、疾病预警，如智能手环结合 AI 分析用户运动、睡眠、心率等数据。",{"id":495,"value":495,"name":496,"intro":497,"add_value":498,"describe":497},6,"Smart Devices","多模态交互：支持语音、手势、眼神等多种交互方式，如 AI 眼镜可通过语音指令实现翻译、搜索功能。\n智能感知与处理：使设备能感知环境、理解用户需求，如智能音箱根据环境噪音自动调节音量。\n个性化服务：根据用户使用习惯和偏好，提供个性化功能与服务，如智能手表为用户定制运动健身计划。","microscope",{"id":500,"value":500,"name":501,"intro":502,"add_value":503,"describe":502},8,"Law & Government","智能法律问答：面向公众或企业用户，提供合规、劳动法、婚姻继承、知识产权等常见法律问题的智能解答。\n合同审查与风险识别：利用大模型分析合同内容，识别潜在风险条款、漏洞或不合理约定，提升合同审核质量。\n法律知识图谱构建：自动梳理法规、案例、条文之间的引用关系，构建语义化知识图谱，支持智能分析和推理。","hammer",{"id":505,"value":505,"name":506,"intro":507,"add_value":508,"describe":507},7,"Education & Training","个性化学习：根据学生学习进度、能力和知识掌握情况，推送个性化学习内容与练习，如智能辅导系统为学生制定专属学习计划。\n智能教学辅助：AI 助教协助教师进行作业批改、答疑解惑，还可分析教学数据，为教师提供教学反馈，优化教学方法。\n虚拟学习环境：利用 AI 创建虚拟实验、历史场景等，让学生沉浸式学习，如在虚拟化学实验室中进行实验操作。","degree-hat",{"id":510,"value":510,"name":511,"intro":512,"add_value":513,"describe":512},5,"Agriculture & Food","作物病虫害识别与防治：通过图像识别分析农作物叶片、果实等症状，识别病虫害类型，给出防治建议，减少产量损失。\n农产品质量检测：利用图像和传感器数据，识别果蔬等农产品的成熟度、外观缺陷，进行自动分级，提高市场竞争力。\n农情监测与预测：利用卫星遥感、气象和传感器数据，结合大模型预测作物长势、干旱、洪涝等农情变化。","ph-farm",{"id":515,"value":515,"name":516,"intro":517,"add_value":518,"describe":517},9,"Retail & E-commerce","智能客服：通过自然语言对话理解用户需求，提供产品推荐、订单查询、退换货支持等服务，提升客户满意度。\n个性化营销推荐：基于用户浏览、购买、偏好等行为数据，生成个性化推荐内容与优惠策略，提高转化率和客单价。\n商品内容生成：自动撰写商品标题、卖点描述、使用说明等内容，适用于海量SKU的内容生产与多语言发布。","buy",{"id":520,"value":520,"name":521,"intro":522,"add_value":523,"describe":8},10,"Security & Protection",null,"safe-shield-line",{"id":525,"value":525,"name":526,"intro":522,"add_value":527,"describe":8},11,"Environment & Climate","weather",{"id":529,"value":529,"name":530,"intro":522,"add_value":531,"describe":8},12,"Energy & Resource","energy-leaf",{"id":533,"value":533,"name":534,"intro":522,"add_value":535,"describe":8},13,"Express & Logistics","speed-outline",{"id":537,"value":537,"name":538,"intro":522,"add_value":539,"describe":8},15,"Sports","baseball-outline",{"id":541,"value":541,"name":542,"intro":522,"add_value":543,"describe":8},16,"General Data","daily-booth",{"id":545,"value":545,"name":546,"intro":522,"add_value":547,"describe":8},17,"Content & Media","media",{"id":549,"value":549,"name":550,"intro":522,"add_value":551,"describe":8},18,"Construction","construction",{"id":553,"value":553,"name":554,"intro":522,"add_value":555,"describe":8},19,"IT & Telecom","tech",{"id":557,"value":557,"name":558,"intro":522,"add_value":498,"describe":8},20,"Science & Research",{"id":560,"value":560,"name":561,"intro":522,"add_value":562,"describe":8},21,"Language & Culture","lang",{"id":564,"unique_code":565,"title":566,"icon":8,"intro":567,"cate":483,"detail":568,"create_time":569,"update_time":570,"price":571,"view_count":549,"download_count":572,"unit":572,"amount":573,"is_create_order":572,"enterprise_id":488,"seo_keywords":574,"seo_description":575,"data_format":576,"file_size":577,"apply_scene":578,"training_task":579,"version":580,"dataset_type_id":510,"dataset_scene_id":529,"sample_file":581,"banner":8,"unit_name":8,"cate_name":449,"icon_url":8,"banner_url":8,"sample_file_url":8,"data_dict":582,"qa_list":639,"sample_metadatas":656,"text_sample_content":704,"enterprise_name":705,"enterprise_logo":706,"data_distribution":707},1229,"251625d652d8f5ea858dfe44f1fa109b","Power System Relay Protection Practice Q&amp;A Dataset","Train and evaluate domain models with answered and explained practice questions on relay protection principles and power engineering applications.","\u003Cp>This dataset contains relay protection practice questions, answers, and explanations for electrical engineering, covering protection principles, fault identification, setting logic, secondary circuits, and substation operations. The web-text records are organized with fields such as knowledge domain, question type, difficulty, key concepts, and reasoning steps for targeted search and filtering. It supports supervised fine-tuning of power engineering question-answering models, knowledge coverage evaluation, and the development of learning support tools.\u003C\u002Fp>","2026-10-15 18:04:17","2026-10-19 17:18:37","0.00",0,5000,"power system relay protection dataset,relay protection Q&amp;A,electrical engineering question bank,relay protection practice questions,power engineering knowledge QA,fault identification training data,relay protection SFT dataset,secondary circuit questions","Practice Q&amp;A on relay protection principles, fault identification, setting logic, and secondary circuits, with answers and explanations for model tuning and","JSON","0.3GB","Power System Protection, Electrical Engineering, Technical Question Answering","Question Answering, Knowledge Reasoning, Explanation Generation","V1.0","rivo\u002Fsample-packages\u002F137adab2-f07d-4933-8c6b-1f96fa7384a1\u002F20261015.zip",[583,588,593,599,604,609,614,619,624,629,634],{"id":572,"name":584,"field":585,"intro":586,"type":587},"File Name","file_name","File name","string",{"id":589,"name":590,"field":591,"intro":592,"type":587},8950,"Answer Text","answer_text","Original answer to the practice question, which may contain an option, judgment, calculation result, or short-answer conclusion.",{"id":594,"name":595,"field":596,"intro":597,"type":598},8951,"Key Concepts","key_concepts","Key relay protection concepts, equipment, parameters, or criteria extracted from the question, answer, and explanation.","array",{"id":600,"name":601,"field":602,"intro":603,"type":587},8952,"SFT Response Text","sft_response","A complete supervised fine-tuning target response that combines the answer and explanation with professional reasoning.",{"id":605,"name":606,"field":607,"intro":608,"type":587},8953,"Question Text","question_text","Original text of a power system relay protection practice question.",{"id":610,"name":611,"field":612,"intro":613,"type":587},8954,"Question Type","question_type","Question format inferred from how the problem is presented and answered.",{"id":615,"name":616,"field":617,"intro":618,"type":598},8955,"Reasoning Steps","reasoning_steps","Ordered steps that organize the explanation into judgments, calculations, references to principles, or derivations of the conclusion.",{"id":620,"name":621,"field":622,"intro":623,"type":587},8956,"SFT Instruction Text","sft_instruction","A user question or domain-specific instruction based on the original question and prepared for supervised fine-tuning.",{"id":625,"name":626,"field":627,"intro":628,"type":587},8957,"Difficulty Level","difficulty_level","Question difficulty based on the breadth of knowledge covered, reasoning complexity, and calculation or analysis requirements.",{"id":630,"name":631,"field":632,"intro":633,"type":587},8958,"Explanation Text","explanation_text","Original explanation of the answer, relay protection principles, fault identification criteria, setting logic, or operational procedures.",{"id":635,"name":636,"field":637,"intro":638,"type":587},8959,"Knowledge Domain","knowledge_domain","Primary professional knowledge domain inferred from the question and explanation.",[640,644,648,652],{"id":641,"question":642,"answer":643},6367,"What does the dataset contain?","It includes relay protection practice questions, answers, and explanations, with structured information such as knowledge domain, question type, difficulty level, key concepts, and reasoning steps.",{"id":645,"question":646,"answer":647},6368,"Which model tasks is it suitable for?","It can support domain-specific supervised fine-tuning for power system relay protection Q&A, answer generation, and problem-solving reasoning. It can also help build professional knowledge retrieval and learning support tools.",{"id":649,"question":650,"answer":651},6369,"What are the dataset size and quality metrics?","The available description does not specify a sample count or quality evaluation metrics. Before use, review the product page for sample previews, field completeness, and quality notes, and validate a sample against your target task.",{"id":653,"question":654,"answer":655},6370,"How can I obtain the dataset, and what are the licensing terms?","Check the platform listing for available versions, delivery options, and license terms. Permissions for commercial use, redistribution, and model training depend on the applicable purchase or license agreement.",[657,675,689],{"id":658,"relate_table":659,"relate_id":660,"file_size":572,"file_name":661,"path":8,"duration":572,"cate":483,"file_format":662,"audio_rate":8,"audio_channel":522,"audio_bit_depth":522,"quality":8,"annotation":663,"cate_name":664,"answer_text":665,"key_concepts":666,"sft_response":667,"question_text":668,"question_type":669,"reasoning_steps":670,"sft_instruction":671,"difficulty_level":672,"explanation_text":673,"knowledge_domain":674},15087,"union_cubo",1828685704,"样例_3.json","json","{\"answer_text\": \"The CT ratio is 400\u002F5=80. (1) The primary-side pickup current is 1.25 x 80=100 A; (2) the secondary current corresponding to the 600 A primary short-circuit current is 600\u002F80=7.5 A; (3) 7.5 A is greater than 1.25 A, so the short-circuit current reaches the pickup value of the overcurrent protection.\", \"key_concepts\": \"[\\\"Current transformer ratio\\\", \\\"Overcurrent protection\\\", \\\"Primary pickup current\\\", \\\"Secondary current conversion\\\", \\\"Operating condition\\\", \\\"Operating time delay\\\"]\", \"sft_response\": \"The CT ratio is K_I=400\u002F5=80. The primary-side pickup current is I_{set,1}=1.25 x 80=100 A; the 600 A primary short-circuit current referred to the secondary side is I_{f,2}=600\u002F80=7.5 A. Because 7.5 A is greater than the relay secondary pickup setting value 1.25 A, the overcurrent protection meets the pickup condition. Note that whether it ultimately trips still needs further determination in combination with the operating time delay, trip output circuit, and blocking conditions.\", \"question_text\": \"A 10 kV feeder is equipped with overcurrent protection, the current transformer ratio is 400\u002F5, and the secondary current corresponding to the relay primary-side equivalent current setting is 1.25 A. If a three-phase short circuit occurs on the feeder and the short-circuit current referred to the CT primary side is 600 A, calculate: (1) the primary-side pickup current of the protection; (2) the CT secondary current corresponding to the 600 A primary short-circuit current; (3) determine whether the fault current reaches the protection pickup value.\", \"question_type\": \"Calculation Question\", \"reasoning_steps\": \"[\\\"Calculate the CT ratio: K_I=400\u002F5=80.\\\", \\\"Multiply the relay secondary setting value 1.25 A by the ratio to obtain the primary-side pickup current 100 A.\\\", \\\"Divide the primary-side short-circuit current 600 A by the ratio to obtain the secondary-side fault current 7.5 A.\\\", \\\"Compare 7.5 A with the secondary pickup setting value 1.25 A and confirm that the fault current meets the pickup condition.\\\", \\\"Explain that reaching the pickup value is not equivalent to immediate tripping; the operating time delay and trip output logic still need to be checked.\\\"]\", \"sft_instruction\": \"Given that the CT ratio of a 10 kV feeder is 400\u002F5, the secondary setting current of the overcurrent relay is 1.25 A, and the primary short-circuit current during a three-phase short circuit is 600 A. Calculate the primary pickup current and the secondary current during the fault, and determine whether the protection picks up.\", \"difficulty_level\": \"Medium\", \"explanation_text\": \"The current transformer ratio is K_I=I_{1N}\u002FI_{2N}=400\u002F5=80. When the relay secondary setting current is referred to the primary side, it should be multiplied by the CT ratio, so the primary pickup current is I_{set,1}=1.25 x 80=100 A. When the fault current is referred to the secondary side, it should be divided by the CT ratio, giving I_{f,2}=600\u002F80=7.5 A. Since 7.5 A exceeds the relay secondary pickup setting of 1.25 A, the protection element meets the pickup condition; actual tripping still needs to be determined in combination with the operating time delay, trip output logic, and other blocking conditions.\", \"knowledge_domain\": \"Protection Setting and Coordination\"}","文本","The CT ratio is 400\u002F5=80. (1) The primary-side pickup current is 1.25 x 80=100 A; (2) the secondary current corresponding to the 600 A primary short-circuit current is 600\u002F80=7.5 A; (3) 7.5 A is greater than 1.25 A, so the short-circuit current reaches the pickup value of the overcurrent protection.","[\"Current transformer ratio\", \"Overcurrent protection\", \"Primary pickup current\", \"Secondary current conversion\", \"Operating condition\", \"Operating time delay\"]","The CT ratio is K_I=400\u002F5=80. The primary-side pickup current is I_{set,1}=1.25 x 80=100 A; the 600 A primary short-circuit current referred to the secondary side is I_{f,2}=600\u002F80=7.5 A. Because 7.5 A is greater than the relay secondary pickup setting value 1.25 A, the overcurrent protection meets the pickup condition. Note that whether it ultimately trips still needs further determination in combination with the operating time delay, trip output circuit, and blocking conditions.","A 10 kV feeder is equipped with overcurrent protection, the current transformer ratio is 400\u002F5, and the secondary current corresponding to the relay primary-side equivalent current setting is 1.25 A. If a three-phase short circuit occurs on the feeder and the short-circuit current referred to the CT primary side is 600 A, calculate: (1) the primary-side pickup current of the protection; (2) the CT secondary current corresponding to the 600 A primary short-circuit current; (3) determine whether the fault current reaches the protection pickup value.","Calculation Question","[\"Calculate the CT ratio: K_I=400\u002F5=80.\", \"Multiply the relay secondary setting value 1.25 A by the ratio to obtain the primary-side pickup current 100 A.\", \"Divide the primary-side short-circuit current 600 A by the ratio to obtain the secondary-side fault current 7.5 A.\", \"Compare 7.5 A with the secondary pickup setting value 1.25 A and confirm that the fault current meets the pickup condition.\", \"Explain that reaching the pickup value is not equivalent to immediate tripping; the operating time delay and trip output logic still need to be checked.\"]","Given that the CT ratio of a 10 kV feeder is 400\u002F5, the secondary setting current of the overcurrent relay is 1.25 A, and the primary short-circuit current during a three-phase short circuit is 600 A. Calculate the primary pickup current and the secondary current during the fault, and determine whether the protection picks up.","Medium","The current transformer ratio is K_I=I_{1N}\u002FI_{2N}=400\u002F5=80. When the relay secondary setting current is referred to the primary side, it should be multiplied by the CT ratio, so the primary pickup current is I_{set,1}=1.25 x 80=100 A. When the fault current is referred to the secondary side, it should be divided by the CT ratio, giving I_{f,2}=600\u002F80=7.5 A. Since 7.5 A exceeds the relay secondary pickup setting of 1.25 A, the protection element meets the pickup condition; actual tripping still needs to be determined in combination with the operating time delay, trip output logic, and other blocking conditions.","Protection Setting and Coordination",{"id":676,"relate_table":659,"relate_id":677,"file_size":572,"file_name":678,"path":8,"duration":572,"cate":483,"file_format":662,"audio_rate":8,"audio_channel":522,"audio_bit_depth":522,"quality":8,"annotation":679,"cate_name":664,"answer_text":680,"key_concepts":681,"sft_response":682,"question_text":683,"question_type":684,"reasoning_steps":685,"sft_instruction":686,"difficulty_level":672,"explanation_text":687,"knowledge_domain":688},15086,1318363260,"样例_2.json","{\"answer_text\": \"Direct opening is strictly prohibited. When the CT secondary circuit is open, the secondary current is forced to interrupt, the core magnetic flux increases significantly, and a dangerous high voltage may be generated on the secondary side, endangering personal safety and possibly causing CT insulation damage, increased core residual magnetism, and failure of protection and measurement circuits. Before handling, power should be cut off, isolation should be applied, or dedicated short-circuiting measures should be used in accordance with site regulations, and relevant protection and safety measures should be confirmed.\", \"key_concepts\": \"[\\\"Current transformer\\\", \\\"CT secondary circuit open\\\", \\\"Secondary induced voltage\\\", \\\"Core magnetic flux\\\", \\\"Protection circuit failure\\\", \\\"Dedicated short-circuiting measures\\\"]\", \"sft_response\": \"When a CT operates normally, the secondary circuit should remain closed, and the secondary current is used to offset the magnetomotive force generated by the primary current. If the secondary circuit is directly opened, the secondary current is interrupted, the core magnetic flux and secondary induced voltage may rise significantly, dangerous high voltage may appear at the open point, and CT insulation damage, increased residual magnetism, and failure of protection and measurement circuits may result. Therefore, the CT secondary circuit must not be directly disconnected when there is current in the primary. Before handling, power outage, isolation, or qualified dedicated short-circuiting measures should be carried out in accordance with on-site regulations, and the impact on relevant protection and measurement circuits should be verified; ordinary wires must not be used for arbitrary short-circuiting or operation.\", \"question_text\": \"During operation of a substation, abnormal contact was found at the secondary circuit terminals of a group of current transformers (CTs) in operation, and the terminals need to be handled. Question: Why is it strictly prohibited to directly open the CT secondary circuit when the primary equipment is energized and current is flowing in the CT primary? What should be focused on when handling such defects?\", \"question_type\": \"Fault Analysis Question\", \"reasoning_steps\": \"[\\\"Identify the fault object as the secondary circuit of an operating CT, not an ordinary low-voltage control circuit.\\\", \\\"Analyze that when the CT works normally, the secondary circuit is closed and has low impedance, and the secondary current has a balancing effect on the primary magnetomotive force.\\\", \\\"Determine that after the secondary circuit opens, the secondary current is interrupted, and the core magnetic flux and secondary induced voltage may rise significantly.\\\", \\\"From this, conclude that direct opening may cause personal electric shock, equipment insulation damage, and abnormal protection and measurement.\\\", \\\"During handling, power outage, isolation, or reliable short-circuiting should be completed according to regulations, and the impact on protection devices should be evaluated.\\\"]\", \"sft_instruction\": \"Analyze why it is strictly prohibited to directly open the CT secondary circuit when there is current in the CT primary, and explain the basic safety principles that should be followed when handling abnormal CT secondary terminals.\", \"difficulty_level\": \"Medium\", \"explanation_text\": \"During normal operation, the magnetomotive force generated by the CT secondary winding is used to offset the magnetomotive force generated by the primary current, and the secondary circuit is approximately in a low-impedance closed state. If the secondary circuit suddenly opens, the secondary current cannot flow, the core magnetic flux and secondary induced electromotive force may rise significantly, and dangerous voltage may also appear at the open point. Therefore, the secondary terminals of a loaded CT must not be directly disconnected or opened. Actual handling must comply with on-site operating regulations, and qualified personnel must confirm the primary system status, the scope of protection impact, and short-circuiting and isolation measures; short-circuiting should use qualified test terminals or dedicated short-circuiting tools, and ordinary wires must not be used for arbitrary operation.\", \"knowledge_domain\": \"Secondary Circuit\"}","Direct opening is strictly prohibited. When the CT secondary circuit is open, the secondary current is forced to interrupt, the core magnetic flux increases significantly, and a dangerous high voltage may be generated on the secondary side, endangering personal safety and possibly causing CT insulation damage, increased core residual magnetism, and failure of protection and measurement circuits. Before handling, power should be cut off, isolation should be applied, or dedicated short-circuiting measures should be used in accordance with site regulations, and relevant protection and safety measures should be confirmed.","[\"Current transformer\", \"CT secondary circuit open\", \"Secondary induced voltage\", \"Core magnetic flux\", \"Protection circuit failure\", \"Dedicated short-circuiting measures\"]","When a CT operates normally, the secondary circuit should remain closed, and the secondary current is used to offset the magnetomotive force generated by the primary current. If the secondary circuit is directly opened, the secondary current is interrupted, the core magnetic flux and secondary induced voltage may rise significantly, dangerous high voltage may appear at the open point, and CT insulation damage, increased residual magnetism, and failure of protection and measurement circuits may result. Therefore, the CT secondary circuit must not be directly disconnected when there is current in the primary. Before handling, power outage, isolation, or qualified dedicated short-circuiting measures should be carried out in accordance with on-site regulations, and the impact on relevant protection and measurement circuits should be verified; ordinary wires must not be used for arbitrary short-circuiting or operation.","During operation of a substation, abnormal contact was found at the secondary circuit terminals of a group of current transformers (CTs) in operation, and the terminals need to be handled. Question: Why is it strictly prohibited to directly open the CT secondary circuit when the primary equipment is energized and current is flowing in the CT primary? What should be focused on when handling such defects?","Fault Analysis Question","[\"Identify the fault object as the secondary circuit of an operating CT, not an ordinary low-voltage control circuit.\", \"Analyze that when the CT works normally, the secondary circuit is closed and has low impedance, and the secondary current has a balancing effect on the primary magnetomotive force.\", \"Determine that after the secondary circuit opens, the secondary current is interrupted, and the core magnetic flux and secondary induced voltage may rise significantly.\", \"From this, conclude that direct opening may cause personal electric shock, equipment insulation damage, and abnormal protection and measurement.\", \"During handling, power outage, isolation, or reliable short-circuiting should be completed according to regulations, and the impact on protection devices should be evaluated.\"]","Analyze why it is strictly prohibited to directly open the CT secondary circuit when there is current in the CT primary, and explain the basic safety principles that should be followed when handling abnormal CT secondary terminals.","During normal operation, the magnetomotive force generated by the CT secondary winding is used to offset the magnetomotive force generated by the primary current, and the secondary circuit is approximately in a low-impedance closed state. If the secondary circuit suddenly opens, the secondary current cannot flow, the core magnetic flux and secondary induced electromotive force may rise significantly, and dangerous voltage may also appear at the open point. Therefore, the secondary terminals of a loaded CT must not be directly disconnected or opened. Actual handling must comply with on-site operating regulations, and qualified personnel must confirm the primary system status, the scope of protection impact, and short-circuiting and isolation measures; short-circuiting should use qualified test terminals or dedicated short-circuiting tools, and ordinary wires must not be used for arbitrary operation.","Secondary Circuit",{"id":690,"relate_table":659,"relate_id":691,"file_size":572,"file_name":692,"path":8,"duration":572,"cate":483,"file_format":662,"audio_rate":8,"audio_channel":522,"audio_bit_depth":522,"quality":8,"annotation":693,"cate_name":664,"answer_text":694,"key_concepts":695,"sft_response":696,"question_text":697,"question_type":698,"reasoning_steps":699,"sft_instruction":700,"difficulty_level":701,"explanation_text":702,"knowledge_domain":703},15085,1914734940,"样例_1.json","{\"answer_text\": \"B。\", \"key_concepts\": \"[\\\"Distance protection\\\", \\\"Measured impedance\\\", \\\"Distance Zone I\\\", \\\"Protection range\\\", \\\"Backup protection\\\"]\", \"sft_response\": \"The correct option is B. Distance protection determines the fault distance based on measured impedance. To ensure selectivity, distance Zone I is usually set to 80%-85% of the total length of the protected line and usually has no intentional time delay; distance Zone II extends to a part of the adjacent line and is set with a certain time delay; distance Zone III serves as backup protection for the protected line and adjacent elements, and its operating time delay is usually longer.\", \"question_text\": \"Regarding three-zone distance protection for a 110 kV transmission line, which of the following statements is correct: A. Distance Zone I usually protects the entire line length and has a long time delay; B. Distance Zone I is usually set to 80%-85% of the total line length and usually operates without intentional time delay; C. Distance Zone II protects only the local end of the protected line and must operate without time delay; D. Distance Zone III is used only to protect the busbar.\", \"question_type\": \"Single-choice question\", \"reasoning_steps\": \"[\\\"Clarify that distance protection reflects the fault distance through measured impedance.\\\", \\\"Considering measurement errors, fault resistance, and external fault effects, Zone I cannot cover the entire line length without sacrificing selectivity.\\\", \\\"According to common setting principles, the protection range of Zone I is usually 80%-85% of the total line length.\\\", \\\"After checking each option, option B conforms to the zone-setting principle of distance protection.\\\"]\", \"sft_instruction\": \"Determine which statement about three-zone distance protection for a 110 kV transmission line is correct, and explain the basic characteristics of distance Zones I, II, and III in terms of protection range and operating time delay.\", \"difficulty_level\": \"Basic\", \"explanation_text\": \"Distance protection determines the fault location based on the measured fault impedance. To avoid the influence of factors such as external faults at the remote busbar, measurement errors, and fault resistance, distance Zone I usually protects only about 80%-85% of the total length of the protected line and operates with a short inherent time or approximately without time delay. Distance Zone II should extend to a part of the adjacent line and have a time delay, while distance Zone III mainly serves as backup protection for the protected line and adjacent elements.\", \"knowledge_domain\": \"Relay Protection Principles\"}","B。","[\"Distance protection\", \"Measured impedance\", \"Distance Zone I\", \"Protection range\", \"Backup protection\"]","The correct option is B. Distance protection determines the fault distance based on measured impedance. To ensure selectivity, distance Zone I is usually set to 80%-85% of the total length of the protected line and usually has no intentional time delay; distance Zone II extends to a part of the adjacent line and is set with a certain time delay; distance Zone III serves as backup protection for the protected line and adjacent elements, and its operating time delay is usually longer.","Regarding three-zone distance protection for a 110 kV transmission line, which of the following statements is correct: A. Distance Zone I usually protects the entire line length and has a long time delay; B. Distance Zone I is usually set to 80%-85% of the total line length and usually operates without intentional time delay; C. Distance Zone II protects only the local end of the protected line and must operate without time delay; D. Distance Zone III is used only to protect the busbar.","Single-choice question","[\"Clarify that distance protection reflects the fault distance through measured impedance.\", \"Considering measurement errors, fault resistance, and external fault effects, Zone I cannot cover the entire line length without sacrificing selectivity.\", \"According to common setting principles, the protection range of Zone I is usually 80%-85% of the total line length.\", \"After checking each option, option B conforms to the zone-setting principle of distance protection.\"]","Determine which statement about three-zone distance protection for a 110 kV transmission line is correct, and explain the basic characteristics of distance Zones I, II, and III in terms of protection range and operating time delay.","Basic","Distance protection determines the fault location based on the measured fault impedance. To avoid the influence of factors such as external faults at the remote busbar, measurement errors, and fault resistance, distance Zone I usually protects only about 80%-85% of the total length of the protected line and operates with a short inherent time or approximately without time delay. Distance Zone II should extend to a part of the adjacent line and have a time delay, while distance Zone III mainly serves as backup protection for the protected line and adjacent elements.","Relay Protection Principles","{\"answer_text\":\"The CT ratio is 400\\\u002F5=80. (1) The primary-side pickup current is 1.25 x 80=100 A; (2) the secondary current corresponding to the 600 A primary short-circuit current is 600\\\u002F80=7.5 A; (3) 7.5 A is greater than 1.25 A, so the short-circuit current reaches the pickup value of the overcurrent protection.\",\"key_concepts\":\"[\\\"Current transformer ratio\\\", \\\"Overcurrent protection\\\", \\\"Primary pickup current\\\", \\\"Secondary current conversion\\\", \\\"Operating condition\\\", \\\"Operating time delay\\\"]\",\"sft_response\":\"The CT ratio is K_I=400\\\u002F5=80. The primary-side pickup current is I_{set,1}=1.25 x 80=100 A; the 600 A primary short-circuit current referred to the secondary side is I_{f,2}=600\\\u002F80=7.5 A. Because 7.5 A is greater than the relay secondary pickup setting value 1.25 A, the overcurrent protection meets the pickup condition. Note that whether it ultimately trips still needs further determination in combination with the operating time delay, trip output circuit, and blocking conditions.\",\"question_text\":\"A 10 kV feeder is equipped with overcurrent protection, the current transformer ratio is 400\\\u002F5, and the secondary current corresponding to the relay primary-side equivalent current setting is 1.25 A. If a three-phase short circuit occurs on the feeder and the short-circuit current referred to the CT primary side is 600 A, calculate: (1) the primary-side pickup current of the protection; (2) the CT secondary current corresponding to the 600 A primary short-circuit current; (3) determine whether the fault current reaches the protection pickup value.\",\"question_type\":\"Calculation Question\",\"reasoning_steps\":\"[\\\"Calculate the CT ratio: K_I=400\\\u002F5=80.\\\", \\\"Multiply the relay secondary setting value 1.25 A by the ratio to obtain the primary-side pickup current 100 A.\\\", \\\"Divide the primary-side short-circuit current 600 A by the ratio to obtain the secondary-side fault current 7.5 A.\\\", \\\"Compare 7.5 A with the secondary pickup setting value 1.25 A and confirm that the fault current meets the pickup condition.\\\", \\\"Explain that reaching the pickup value is not equivalent to immediate tripping; the operating time delay and trip output logic still need to be checked.\\\"]\",\"sft_instruction\":\"Given that the CT ratio of a 10 kV feeder is 400\\\u002F5, the secondary setting current of the overcurrent relay is 1.25 A, and the primary short-circuit current during a three-phase short circuit is 600 A. Calculate the primary pickup current and the secondary current during the fault, and determine whether the protection picks up.\",\"difficulty_level\":\"Medium\",\"explanation_text\":\"The current transformer ratio is K_I=I_{1N}\\\u002FI_{2N}=400\\\u002F5=80. When the relay secondary setting current is referred to the primary side, it should be multiplied by the CT ratio, so the primary pickup current is I_{set,1}=1.25 x 80=100 A. When the fault current is referred to the secondary side, it should be divided by the CT ratio, giving I_{f,2}=600\\\u002F80=7.5 A. Since 7.5 A exceeds the relay secondary pickup setting of 1.25 A, the protection element meets the pickup condition; actual tripping still needs to be determined in combination with the operating time delay, trip output logic, and other blocking conditions.\",\"knowledge_domain\":\"Protection Setting and Coordination\"}","MOBIUSI INC","https:\u002F\u002Fstatic.mobiusi.com\u002Fmobiwusi\u002F20250829\u002F7bf4ac62b4533e2b809998a6f1c5491e.png?Expires=1792463130&OSSAccessKeyId=LTAI5tH8MQqhgeiAtrzCHrxM&Signature=v6Tr8jBrdm4s5wU1SnnyGsYg%2Bhw%3D&x-oss-process=image%2Fresize%2Cm_fill%2Cw_35%2Ch_35",[708,714],{"type":709,"title":710,"count_data":711},"bar","Length distribution",[712],{"name":713,"value":483},"1k lower",{"type":715,"title":716,"count_data":717},"pie","Language distribution",[718],{"name":719,"value":483},"English"]